Calculate BTU requirements for heating or cooling any room or whole house. Accounts for square footage, ceiling height, climate zone, insulation quality, and sun exposure.
ft
ft
sq ft
YOUR RESULTS
Cooling BTU
—
BTU/hr
Tonnage
—
tons AC
Area
—
sq ft
BTU per sq ft
—
BTU/sq ft
Heating BTU
—
BTU/hr
Recommended Unit
—
approx size
AC Unit Size Reference
BTU Range
Tons
Area (avg)
Typical Use
5,000–8,000
—
100–350 sq ft
Window unit / small room
18,000
1.5 ton
700–1,000 sq ft
Small home / apartment
24,000
2 ton
1,000–1,300 sq ft
Small home
30,000
2.5 ton
1,300–1,600 sq ft
Medium home
36,000
3 ton
1,600–1,900 sq ft
Medium-large home
48,000
4 ton
1,900–2,500 sq ft
Large home
60,000
5 ton
2,500–3,300 sq ft
Very large home
Select the Single Room tab for window AC units, mini-splits, and room heaters, or the Whole House tab for central AC and heat pump sizing. The result is a planning estimate, actual HVAC sizing requires a Manual J calculation by a licensed HVAC engineer, which accounts for ductwork, infiltration, and local design temperatures. Use this calculator to get in the right ballpark before calling for quotes.
How to Calculate BTU Requirements
The baseline rule of thumb is 20 BTU per square foot for cooling in an average climate with 8 ft ceilings and average insulation. Adjustments multiply this baseline: a vaulted 12 ft ceiling needs 50% more BTU than an 8 ft ceiling of the same footprint. A sunny south-facing room needs 10% more. An older home with poor insulation needs 20% more. These factors compound quickly, a 15×12 sunny room in a poorly insulated older home needs significantly more than the baseline 3,600 BTU would suggest.
What Drives Your BTU Number
The diagram below shows how the baseline square-footage number gets adjusted up or down by the factors this calculator asks about.
The Oversizing Problem: Why Bigger Isn't Better
Condition
Too Small
Just Right
Too Large
Temperature control
Can't maintain temp on hot days
Reaches setpoint, cycles normally
Reaches setpoint too fast, short-cycles
Humidity
Runs constantly; OK for humidity
Good dehumidification
Cools too fast to dehumidify; clammy air
Equipment wear
Constant run; motor wear
Normal cycle life
Short-cycling wears compressor faster
Energy use
High; runs constantly
Optimized
High; frequent starts draw surge current
Comfort
Hot on peak days
Consistent comfort
Cold and humid; uncomfortable
Tons vs. BTU
Air conditioning capacity is expressed in "tons": a unit that dates to the era of ice cooling, where one ton of ice absorbs 12,000 BTU per hour as it melts. One AC ton = 12,000 BTU/hr. A 2.5-ton unit provides 30,000 BTU/hr of cooling. Residential central AC runs 1.5 to 5 tons, in 0.5-ton increments. Mini-splits are available in smaller increments, as small as 6,000 BTU (0.5 ton), making them better suited for additions and individual rooms where whole-home systems are oversized.
Cooling vs. Heating
Cooling and heating loads are not the same number. Heat pumps and furnaces are sized in heating BTU output, not cooling. For heating in cold climates, multiply the cooling BTU result by 1.25–1.5 as a rough approximation. A furnace for a 1,800 sq ft home in Minnesota needs significantly more heating capacity than a Florida home of the same size needs cooling capacity. Manual J calculations treat these separately using local design temperatures.
Cooling System Types by BTU Range
The right equipment type depends as much on your BTU range as it does on preference. Here's how the common options line up:
System Type
Typical BTU Range
Best For
Window unit
5,000–14,000
Single room, rental, no ductwork available
Portable AC
8,000–14,000
Temporary cooling, no permanent install
Mini-split (single zone)
6,000–24,000
Additions, garages, rooms without ducts
Mini-split (multi-zone)
18,000–48,000
Whole small home, ductless whole-house cooling
Central AC / heat pump
18,000–60,000
Whole home with existing or new ductwork
Mini-splits have become popular for additions and older homes without ductwork because they're sized in smaller increments than central systems and avoid the cost of running new ducts. A single-zone mini-split can also handle spaces where a central system would be significantly oversized, like a converted garage or a home office addition.
Common BTU Sizing Mistakes
Using square footage alone to size an AC unit. Area is just the starting point. Ceiling height, insulation, window count and orientation, climate zone, and whether the space is above a garage or below a vaulted ceiling all shift the number significantly. A 500 sq ft sunroom with floor-to-ceiling south-facing glass in Phoenix needs 3–4× the BTU of a 500 sq ft interior bedroom in the same house.
Sizing up "just to be safe." An oversized AC cools too fast, doesn't run long enough to remove humidity, and short-cycles, wearing the compressor and leaving the air cold and clammy. Bigger is genuinely worse for comfort in humid climates. Size for the actual load, not the maximum possible load.
Not accounting for the Manual J requirement. Any permitted HVAC installation in new construction requires a Manual J load calculation, not a BTU/sq ft rule of thumb. If your contractor is sizing a new system without running Manual J, ask why. It's required by ACCA (the HVAC trade association) and increasingly required by code in all climate zones.
Sizing a heat pump by cooling tons only. A heat pump must be sized to meet the heating load in your climate, not just the cooling load. In cold climates, the heating requirement often exceeds the cooling requirement, which drives system size up. A heat pump sized only for cooling will underperform in winter, especially below 35°F where most standard heat pumps lose efficiency rapidly.
Practical note: This calculator uses the simplified Manual S method for planning estimates. For a final system selection, always have a licensed HVAC contractor run Manual J (load calculation), Manual S (equipment selection), and Manual D (duct design). These three documents together, not the BTU/sq ft rule, are the correct way to size a residential HVAC system, and they're required for most permitted installations.
A 1,500 sq ft house in a moderate climate with average insulation needs approximately 30,000 BTU (2.5 tons) for cooling. In a hot climate like Florida or Texas, increase to 36,000 BTU (3 tons). In a cold climate with good insulation, 24,000 BTU may be adequate. These are rough starting points, the actual number shifts based on ceiling height, window area, orientation, and insulation quality. Always have a Manual J calculation done before purchasing a new central system.
What happens if my AC is too big or too small? ▾
An oversized AC reaches setpoint temperature too quickly and shuts off before completing a full dehumidification cycle, leaving the air cold but humid and clammy, which is genuinely uncomfortable in humid climates. It also short-cycles, wearing out the compressor faster. An undersized unit runs constantly, can't maintain temperature on peak summer days, and has higher energy costs. Neither scenario is comfortable. Proper sizing is more important than most homeowners realize.
How many BTU for a 12×12 room? ▾
A 12×12 room (144 sq ft) in average conditions needs approximately 5,000–6,000 BTU for cooling. A sunny south-facing room or one in a hot climate warrants 6,000–8,000 BTU. A shaded, well-insulated room may be fine with 5,000 BTU. A 5,000–6,000 BTU window unit is the most common choice. For a mini-split, the smallest available size (6,000 BTU / 0.5 ton) will usually be slightly oversized for a single 12×12 room but is typically the minimum available size.
What is the difference between a BTU and a ton of AC? ▾
One ton of air conditioning = 12,000 BTU/hr. The "ton" unit dates to the era of ice cooling: one ton of ice absorbs about 288,000 BTU as it melts over 24 hours, which is 12,000 BTU/hr. Central AC systems are sold in 0.5-ton increments: 1.5 ton (18,000 BTU), 2 ton (24,000), 2.5 ton (30,000), 3 ton (36,000), up to 5 ton (60,000) for residential use. Window units and mini-splits are usually labeled in BTU directly.
Do I need a Manual J calculation for a new AC system? ▾
Yes, for any permitted new construction or complete system replacement, a Manual J load calculation is required by ACCA standards and increasingly required by local building codes. It accounts for local design temperatures, duct losses, infiltration rates, internal heat gains, and building envelope details that a simple BTU/sq ft formula can't capture. A contractor who sizes your system without Manual J is cutting a corner, and a wrong-sized system is one of the most common sources of HVAC complaints after installation.
How many BTU does a mini-split need for a garage conversion? ▾
A typical 400 to 500 sq ft garage conversion needs roughly 9,000 to 12,000 BTU, but garages often warrant extra capacity beyond the standard 20 BTU/sq ft rule since they usually have less insulation than the rest of the house and sometimes a single-pane or uninsulated garage door acting as a large heat-loss surface. If the garage door itself isn't insulated, budget for 25 to 30 BTU per sq ft instead of the standard 20, or plan to add door insulation before sizing the system.