Free Construction Tool

Generator Size Calculator

Reviewed and updated: August 2026

Select the appliances you need to power and instantly calculate required running watts, starting watts, and the recommended generator size. Covers portable and standby generators.

Click to select appliances you need to power. Adjust quantities as needed.

YOUR RESULTS
Running Watts
—
watts
Starting Watts
—
watts peak
Recommended Size
—
watts
Generator Type
—
Items Selected
—
appliances
Est. Fuel Use
—
gal/hr (gas)

Click each appliance you need to run during a power outage, adjust quantities, and click Calculate. The result shows both running watts (what everything needs continuously) and starting watts (the surge required when motors start). Your generator must handle the starting watt surge, which is often 2-3x the running watt load for motor-driven appliances like refrigerators, well pumps, and AC units.

Running Watts vs. Starting Watts

Every motor-driven appliance requires 2-3x more watts to start than to run continuously. A refrigerator running at 150 watts may need 450-600 watts to start. A 1 HP well pump running at 1,000 watts needs 2,500-3,000 watts to start. Your generator must handle the highest starting surge while everything else is already running. Size your generator for the largest single surge on top of your running total, not running watts alone, and not the sum of every appliance's surge added together.

TIME WATTS GENERATOR CAPACITY: 3,500W RUNNING: 950W (fridge + furnace fan) PEAK: 3,350W (sump pump starting) SETTLED: 1,750W (all three running)
Peak demand is a brief spike, not a sustained load: the generator only needs to cover the highest moment, not every surge added together.

Generator Type Comparison

TypeWattage RangeFuelBest ForKey Limitation
Inverter generator1,000–4,500WGasSensitive electronics, camping, quiet operationHigher cost per watt; limited capacity
Portable conventional3,500–12,000WGas / dual fuelMost homeowners; power outage essentialsMust run outside; manual start
Large portable10,000–15,000WGas / propaneWhole-home partial coverage; job sitesHeavy; high fuel consumption
Standby (home)7,000–20,000WNatural gas / propaneAutomatic whole-home backup$5,000–$15,000 installed; permit required
Standby (large)20,000–150,000WNatural gas / dieselCommercial; large homes with central ACHighest cost; requires electrician

Estimated Fuel Consumption

Generator SizeAt 25% LoadAt 50% LoadAt 100% Load5-gal Can Lasts
3,500W portable0.3 gal/hr0.5 gal/hr0.7 gal/hr7–16 hrs
5,000W portable0.4 gal/hr0.6 gal/hr1.0 gal/hr5–12 hrs
7,500W portable0.6 gal/hr0.9 gal/hr1.4 gal/hr3.5–8 hrs
10,000W portable0.7 gal/hr1.1 gal/hr1.7 gal/hr3–7 hrs
14kW standby1.0 gal/hr1.6 gal/hr2.4 gal/hrNatural gas, continuous supply

Transfer Switch: Not Optional

Never connect a portable generator directly to your home's wiring without a transfer switch. Without one, power from the generator can back-feed through the meter to the street, energizing downed power lines at full voltage and electrocuting utility workers trying to restore power. A manual transfer switch costs $200–$500 installed by a licensed electrician. An interlock kit (code-compliant in many jurisdictions) runs $50–$150 plus installation. Both are required for any direct connection to your home's electrical panel.

Common Generator Sizing Mistakes

Load Management and Staggering Startups

The "largest single surge" rule this calculator uses assumes appliances start one at a time, which is how most households naturally operate, but it's worth understanding why that assumption matters and how to protect it in practice. If your well pump and central AC compressor happened to start in the exact same instant, their surges would stack, and even a well-sized generator could stall or trip its breaker.

In practice, this is rarely a problem for typical portable generator setups, since appliances cycle on and off independently based on their own thermostats, float switches, and timers, and true simultaneous starts are uncommon. But if you're running several large motor loads on one generator, a few precautions help: avoid manually switching on multiple large appliances at once when using a manual transfer switch, stagger big loads (start the well pump, let it settle, then turn on the AC) when you have manual control, and consider a soft-start device for large compressors, which spreads out the current draw over a second or two instead of one instantaneous spike. For standby generators serving a whole home with multiple large HVAC loads, a load management module is a common and effective solution, automatically sequencing startups so they never overlap.

Watts, Amps, and Generator Ratings

Generator capacity is sometimes listed in watts and sometimes in amps, which causes confusion when comparing units or checking whether a specific appliance will work. The relationship is straightforward: watts equal volts multiplied by amps. Most household circuits run at 120 volts, so a generator rated for 30 amps at 120V provides 3,600 watts (30 x 120). Larger generators often provide both 120V and 240V output; a 240V circuit at the same amperage delivers twice the wattage, which is why appliances like electric dryers, well pumps, and central AC units (which typically run on 240V) need a generator with 240V output capability, not just a high wattage rating on the 120V side.

Also check a generator's rated (running) watts versus its surge (starting) watts separately; these are usually listed as two different numbers on the spec sheet or nameplate, such as "5,000W rated / 6,250W surge." Your appliance running total needs to fit under the rated watts, while your peak demand (running total plus the largest single surge) needs to fit under the surge rating, not the rated watts figure.

Safety reminder: Run your portable generator at least 20 feet from any door, window, or vent, and point the exhaust away from the house. Install battery-operated carbon monoxide detectors on every floor, especially if you plan to use a generator. CO is odorless and colorless; by the time you feel symptoms, you may not be able to move. This is not optional safety advice; it's the difference between a power outage inconvenience and a fatality.
Frequently Asked Questions
What size generator do I need for my house? ▾
For essential circuits only (refrigerator, some lights, phone charging, sump pump): 3,500–5,000 watts. For moderate comfort (add a window AC unit or furnace fan): 7,500–10,000 watts. For whole-home backup including central AC: 14,000–20,000 watts standby. Use this calculator with your specific appliances for a personalized number; the answer varies enormously based on what you need to power.
How much fuel does a generator use? ▾
A typical 5,000-watt generator at 50% load uses about 0.6–0.7 gallons of gasoline per hour. At full load, expect 0.9–1.0 gallons per hour. A 5-gallon gas can lasts 5–8 hours at moderate load. For a 72-hour outage running 18 hours per day, you need roughly 32–38 gallons. Always store fuel in approved containers with fuel stabilizer, and rotate it every 6–12 months. Stale fuel is the leading cause of portable generator starting failures.
Can I run a central air conditioner on a generator? ▾
Yes, but it requires a large generator. A 3-ton (36,000 BTU) central AC compressor draws 3,500 running watts and 10,500–12,000 starting watts. That means your generator needs at least 12,000–14,000 watts of surge capacity just for the AC, plus additional running watts for everything else. Most portable generators can't handle central AC; a 14–20 kW standby generator is typically required for whole-home cooling backup. Window AC units are much more generator-friendly at 1,000–1,500 running watts.
Do I need a transfer switch for my generator? ▾
Yes, any connection to your home's electrical panel requires a transfer switch or interlock kit. Running cords directly from a generator to appliances doesn't require a transfer switch. But connecting a generator to your panel without one allows electricity to back-feed through the meter to the street, which can electrocute utility workers. A manual transfer switch costs $200–$500 installed. A generator interlock kit costs $50–$150 plus installation and is code-approved in most jurisdictions.
What is the difference between a portable and standby generator? ▾
A portable generator runs on gasoline, must be manually started, requires outdoor placement, needs refueling every 8–12 hours, and connects to your home via extension cords or a manual transfer switch. A standby generator is permanently installed, runs on natural gas or propane (no refueling), starts automatically within 30 seconds of a power outage, and shuts off automatically when utility power returns. Standbys cost $5,000-$15,000 installed but require no manual intervention, a major advantage in severe weather or for households where manual operation isn't practical.