Calculate common rafter length, ridge cut angle, plumb cut, bird's mouth seat cut, and tail length for any roof pitch and span. Live diagram included.
Enter your building width (outside to outside of wall plates), roof pitch, eave overhang, and ridge board thickness. The calculator returns the rafter run (after deducting half the ridge), rise, full rafter length, plumb cut and seat cut angles, the rafter multiplier, and total length including tail. The live diagram shows the triangle geometry for visual reference.
The rafter run = (building width ÷ 2) minus half the ridge board thickness. Rafter length = run × rafter multiplier (the hypotenuse factor for your pitch). The multiplier is √(rise² + 12²) ÷ 12. For a 6/12 pitch: √(36+144) ÷ 12 = √180 ÷ 12 = 1.118. A 12 ft run × 1.118 = 13.42 ft (161" rafter) before adding the tail overhang.
Worked example: 24 ft wide building, 6/12 pitch, 12" overhang, 2× ridge board (1.5"). Run = (24 × 12 ÷ 2) − 0.75 = 143.25". Rise = 143.25 × (6/12) = 71.6". Rafter length = √(143.25² + 71.6²) = 160.2". Tail = √(12² + 6²) = 13.4". Total with tail = 173.6" = 14'-5.6".
| Pitch | Multiplier | Plumb Cut | Seat Cut | Rise per 12" Run |
|---|---|---|---|---|
| 2/12 | 1.0138 | 9.46° | 80.54° | 2" |
| 3/12 | 1.0308 | 14.04° | 75.96° | 3" |
| 4/12 | 1.0541 | 18.43° | 71.57° | 4" |
| 5/12 | 1.0833 | 22.62° | 67.38° | 5" |
| 6/12 | 1.1180 | 26.57° | 63.43° | 6" |
| 7/12 | 1.1577 | 30.26° | 59.74° | 7" |
| 8/12 | 1.2019 | 33.69° | 56.31° | 8" |
| 9/12 | 1.2500 | 36.87° | 53.13° | 9" |
| 10/12 | 1.3017 | 39.81° | 50.19° | 10" |
| 12/12 | 1.4142 | 45.00° | 45.00° | 12" |
The plumb cut (ridge cut) is the vertical cut at the top where the rafter meets the ridge board: set your circular saw bevel to this angle. The seat cut (bird's mouth level cut) is the horizontal cut that bears on the top plate: it's always 90° minus the plumb cut. Both cuts together form the bird's mouth notch.
The seat cut depth (the vertical face of the bird's mouth) should not exceed one-third of the rafter depth. For a 2×6 rafter (5.5" actual depth): max seat cut = 5.5 ÷ 3 = 1.83". Cutting deeper than this weakens the rafter at the bearing point and is a common cause of rafter cracking. The standard bird's mouth uses a 1–1.5" plumb cut depth to give a clean 3/4" to 1" bearing seat on the top plate.
Rafter size and spacing must handle the load above (roof weight, snow load, live load) without excessive deflection. This table gives typical maximum spans for common rafter sizes at 16" on-center spacing under moderate snow load (actual spans depend on species, grade, snow load, and local code, always verify with span tables or an engineer for your specific conditions):
| Rafter Size | Typical Max Span (16" OC) | Common Use |
|---|---|---|
| 2×6 | ~10 to 12 ft | Sheds, porches, light structures |
| 2×8 | ~13 to 16 ft | Standard residential roofs |
| 2×10 | ~17 to 20 ft | Wider spans, steeper pitches |
| 2×12 | ~20 to 24 ft | Long spans, cathedral ceilings |
Steeper pitches generally allow slightly longer spans for the same rafter size, since more of the load is carried in compression along the rafter's length rather than as pure bending. Always check your local span tables (most jurisdictions use the tables published in the IRC) rather than relying on these general ranges for a permitted project.
This calculator handles stick-built common rafters, but roof trusses are the more common choice in new construction. Understanding the tradeoff helps you decide which applies to your project.
| Factor | Stick-Framed Rafters | Trusses |
|---|---|---|
| Design flexibility | High: easy to accommodate vaulted ceilings, skylights, dormers | Lower: engineered per job, changes are costly |
| Labor | More on-site cutting and fitting time | Faster installation; pre-built off-site |
| Interior space | Allows open, vaulted ceilings | Webbing typically requires a flat ceiling below |
| Cost | Higher labor, lower material | Lower labor, engineered material cost |
| Best for | Additions, remodels, custom rooflines, cathedral ceilings | New construction with standard roof shapes |
Additions and remodels frequently use stick-framed rafters even when the original house was truss-built, since matching an existing roofline or working around existing structure is often easier with cut-to-fit rafters than with a custom truss order.
Planning a related project? See our roof pitch calculator and stud calculator for wall framing.