Skylight Calculator – Rough Opening, Header, Flashing & Checklist

Reviewed and updated: August 2026

Calculate rough opening dimensions, header size, jack rafters, flashing perimeter, and get a complete installation checklist for any skylight project.

Enter your skylight unit size, roof pitch, ceiling type, and mounting style to get a full set of framing and installation dimensions. Always verify against the manufacturer's installation instructions before cutting.

Unit size, not rough opening
in
Unit size, not rough opening
in
Rise per 12 inches of run
Affects curb and flashing
Determines if a light shaft is needed
Existing rafter OC spacing
Floor-to-roof deck distance
in
For flashing and material totals
units
FRAMING DIMENSIONS
Rough Opening Width
—
inches
Rough Opening Length
—
inches
Header Size
—
each end
Jack Rafters
—
pieces
Flashing Perimeter
—
linear ft (per unit)
Light Shaft Area
—
sq ft (approx)
Curb Height
—
inches min.
Total Flashing (all units)
—
linear ft

Installation Checklist

    Deck-Mount vs. Curb-Mount Skylights

    The two most common skylight mounting systems have different framing requirements, flashing approaches, and performance characteristics. Choosing the right one upfront avoids costly rework during installation.

    Deck-Mount Skylights

    Deck-mount skylights (sometimes called self-flashing or low-profile skylights) sit directly on the roof deck surface with an integrated flashing flange. The flange overlaps the surrounding roofing material and sheds water without a raised curb. They have a lower profile, often 3-4 inches above the roof surface, and are better suited to pitches of 3/12 and above. Most residential fixed skylights from major manufacturers are deck-mount. Installation is faster when using the manufacturer's flashing kit, which is engineered specifically for each unit size.

    Curb-Mount Skylights

    Curb-mount skylights sit on a raised wood frame (the curb) that lifts the glazing unit above the roof surface. The curb is typically built from pressure-treated 2×6 lumber, with a minimum height of 4 inches above the finished roofing surface to prevent water intrusion. Curb-mount systems are more common on low-slope roofs (2/12–4/12), commercial applications, and replacement installations where an existing curb is already present. Flashing wraps the curb perimeter and requires careful step, counter, and saddle flashing at the uphill end.

    FeatureDeck-MountCurb-Mount
    Minimum pitch3/12 (most units)2/12 (some units)
    Profile height3–4" above roof6"+ above roof
    FlashingIntegrated flange + kitWrapped curb, step/counter
    DIY friendlinessHigher (kit-based)Lower (more custom work)
    Common useResidential, new constructionLow slope, commercial, retrofit

    How to Size a Skylight Rough Opening

    The rough opening is always larger than the skylight unit size. Manufacturers specify the exact rough opening for each product; always check the installation manual. As a general rule:

    Rough opening width = unit width + 3" (for framing clearance)

    Rough opening length = unit length + 3" (for framing clearance)

    The rough opening must land between existing rafters or require cutting one or more rafters and installing headers. If the opening width fits within one rafter bay (e.g., 14.5" between 16" OC rafters or 22.5" between 24" OC rafters), no rafters need to be cut. If the opening is wider, you'll need to cut rafters and install doubled headers at each end of the opening, supported by jack rafters on each side.

    Header sizing follows standard beam span tables. For most residential skylight openings up to 48 inches wide, doubled 2×8 or 2×10 headers are typical. Wider openings or heavy snow load areas may require engineered headers; confirm with your local building department.

    Roof Pitch and Skylight Performance

    Roof pitch affects skylight performance in several important ways beyond just water drainage.

    Light Shafts: Straight, Angled, and Splayed

    When a skylight is installed above a flat ceiling with attic space between, a light shaft must be built to direct light from the roof opening to the ceiling opening. The shaft type affects how much light reaches the room and how the ceiling opening looks.

    Straight Shaft

    A straight shaft runs vertically from roof to ceiling, with the same dimensions at top and bottom. It delivers the most focused light beam and is the simplest to build, but the ceiling opening is the same size as the skylight unit, limiting light spread into the room.

    Angled (Splayed) Shaft

    An angled or splayed shaft widens as it descends toward the ceiling, creating a larger ceiling opening and spreading light more broadly into the room. The angles can be splayed on one, two, three, or all four sides. A splayed shaft is more complex to frame and drywall but significantly improves light quality. The ceiling opening on a fully splayed shaft can be 50–100% larger than the skylight unit itself.

    Sun Tunnel / Tubular Skylight

    For rooms where conventional shaft framing isn't practical (small closets, interior bathrooms, hallways), a tubular skylight (sun tunnel) uses a reflective tube to channel daylight from a small dome on the roof to a diffuser in the ceiling. These require no structural framing changes beyond the roof penetration and are highly efficient at directing light, though they don't provide a view of the sky.

    Flashing: The Most Important Part of Skylight Installation

    More skylight failures come from improper flashing than from any other cause. A skylight that leaks is almost always a flashing problem, not a glazing or frame problem. Flashing must be installed in the correct sequence; out of sequence, even correct materials will leak.

    WATER FLOWS DOWNHILL 5 SKYLIGHT 4 1 2 3 1. SILL FLASHING (first) 2-3. STEP FLASHING (alternate with shingle courses) 4. HEAD FLASHING (last) 5. CRICKET (if over 30" wide, pitch below 7/12) Each layer overlaps the one below it, like shingles, so water always sheds downhill.
    Flashing installation sequence for a deck-mount skylight, numbered in the order each piece is installed.

    The correct installation sequence for a deck-mount skylight with asphalt shingles:

    Always use the manufacturer's flashing kit for the specific unit. Universal or aftermarket kits may not provide the correct geometry for each unit size and can void the warranty.

    Common Skylight Installation Mistakes

    Planning Skylight Costs

    Skylight unit costs range from $150–$500 for standard fixed residential units to $800–$3,000+ for venting, solar-powered, or large custom units. Installation labor typically adds $500–$1,500 per unit depending on accessibility, shaft complexity, and roofing material. Light shaft framing and drywall adds $300–$800 depending on height and splay. Always budget for permits, flashing kit, and any deck repairs discovered after opening the roof.

    Need help estimating total project cost? Read our project cost estimation guide.

    Frequently Asked Questions
    What size rough opening do I need for a skylight? ▾
    The rough opening is typically the skylight unit size plus about 3 inches in each dimension, but always confirm with the manufacturer's installation manual for the specific unit you're installing. Different brands and product lines specify different clearances. The rough opening must be framed with headers at each end and jack rafters on each side if any full rafters are cut to create the opening.
    What is the minimum roof pitch for a skylight? ▾
    Most deck-mount skylights require a minimum roof pitch of 3/12. Below this, water drains too slowly and can work back under the flashing at the sill. Some curb-mount units are rated to 2/12 with additional waterproofing requirements. Always check the specific product's minimum pitch rating; installing a skylight below its rated minimum voids the warranty and creates a high leak risk.
    What is the difference between deck-mount and curb-mount skylights? ▾
    Deck-mount skylights have an integrated flashing flange and sit directly on the roof deck: lower profile, easier to install with a manufacturer kit, and standard for most residential new construction on pitches of 3/12 and above. Curb-mount skylights sit on a raised wood frame (the curb) built from the roof deck up, better for low-slope applications, commercial use, and replacement projects where a curb already exists. Curb-mount installations require more custom flashing work around the curb perimeter.
    Do I need a permit to install a skylight? ▾
    In most jurisdictions, yes. Installing a skylight involves cutting structural roof members (rafters), modifying the building envelope, and creating a new roof penetration, all of which typically require a building permit. Some areas also require an energy compliance check since skylights affect a home's thermal performance. Check with your local building department before starting. Unpermitted skylight work can create problems at resale and may not be covered by homeowner's insurance if a leak causes damage.
    How do I prevent a skylight from leaking? ▾
    Proper flashing installation in the correct sequence is the single most important factor. Install sill flashing first, step flashing up both sides alternating with shingles, and head flashing last. Use the manufacturer's flashing kit for your specific unit, not a universal aftermarket kit. Install self-adhering ice-and-water shield around the full opening. For skylights wider than 30 inches on pitches below 7/12, install a saddle (cricket) behind the uphill end. Inspect and reseal the perimeter caulk every 5-7 years as part of routine roof maintenance.