Reviewed and updated: August 2026
Calculate rough opening dimensions, header size, jack rafters, flashing perimeter, and get a complete installation checklist for any skylight project.
Enter your skylight unit size, roof pitch, ceiling type, and mounting style to get a full set of framing and installation dimensions. Always verify against the manufacturer's installation instructions before cutting.
The two most common skylight mounting systems have different framing requirements, flashing approaches, and performance characteristics. Choosing the right one upfront avoids costly rework during installation.
Deck-mount skylights (sometimes called self-flashing or low-profile skylights) sit directly on the roof deck surface with an integrated flashing flange. The flange overlaps the surrounding roofing material and sheds water without a raised curb. They have a lower profile, often 3-4 inches above the roof surface, and are better suited to pitches of 3/12 and above. Most residential fixed skylights from major manufacturers are deck-mount. Installation is faster when using the manufacturer's flashing kit, which is engineered specifically for each unit size.
Curb-mount skylights sit on a raised wood frame (the curb) that lifts the glazing unit above the roof surface. The curb is typically built from pressure-treated 2×6 lumber, with a minimum height of 4 inches above the finished roofing surface to prevent water intrusion. Curb-mount systems are more common on low-slope roofs (2/12–4/12), commercial applications, and replacement installations where an existing curb is already present. Flashing wraps the curb perimeter and requires careful step, counter, and saddle flashing at the uphill end.
| Feature | Deck-Mount | Curb-Mount |
|---|---|---|
| Minimum pitch | 3/12 (most units) | 2/12 (some units) |
| Profile height | 3–4" above roof | 6"+ above roof |
| Flashing | Integrated flange + kit | Wrapped curb, step/counter |
| DIY friendliness | Higher (kit-based) | Lower (more custom work) |
| Common use | Residential, new construction | Low slope, commercial, retrofit |
The rough opening is always larger than the skylight unit size. Manufacturers specify the exact rough opening for each product; always check the installation manual. As a general rule:
Rough opening width = unit width + 3" (for framing clearance)
Rough opening length = unit length + 3" (for framing clearance)
The rough opening must land between existing rafters or require cutting one or more rafters and installing headers. If the opening width fits within one rafter bay (e.g., 14.5" between 16" OC rafters or 22.5" between 24" OC rafters), no rafters need to be cut. If the opening is wider, you'll need to cut rafters and install doubled headers at each end of the opening, supported by jack rafters on each side.
Header sizing follows standard beam span tables. For most residential skylight openings up to 48 inches wide, doubled 2×8 or 2×10 headers are typical. Wider openings or heavy snow load areas may require engineered headers; confirm with your local building department.
Roof pitch affects skylight performance in several important ways beyond just water drainage.
When a skylight is installed above a flat ceiling with attic space between, a light shaft must be built to direct light from the roof opening to the ceiling opening. The shaft type affects how much light reaches the room and how the ceiling opening looks.
A straight shaft runs vertically from roof to ceiling, with the same dimensions at top and bottom. It delivers the most focused light beam and is the simplest to build, but the ceiling opening is the same size as the skylight unit, limiting light spread into the room.
An angled or splayed shaft widens as it descends toward the ceiling, creating a larger ceiling opening and spreading light more broadly into the room. The angles can be splayed on one, two, three, or all four sides. A splayed shaft is more complex to frame and drywall but significantly improves light quality. The ceiling opening on a fully splayed shaft can be 50–100% larger than the skylight unit itself.
For rooms where conventional shaft framing isn't practical (small closets, interior bathrooms, hallways), a tubular skylight (sun tunnel) uses a reflective tube to channel daylight from a small dome on the roof to a diffuser in the ceiling. These require no structural framing changes beyond the roof penetration and are highly efficient at directing light, though they don't provide a view of the sky.
More skylight failures come from improper flashing than from any other cause. A skylight that leaks is almost always a flashing problem, not a glazing or frame problem. Flashing must be installed in the correct sequence; out of sequence, even correct materials will leak.
The correct installation sequence for a deck-mount skylight with asphalt shingles:
Always use the manufacturer's flashing kit for the specific unit. Universal or aftermarket kits may not provide the correct geometry for each unit size and can void the warranty.
Skylight unit costs range from $150–$500 for standard fixed residential units to $800–$3,000+ for venting, solar-powered, or large custom units. Installation labor typically adds $500–$1,500 per unit depending on accessibility, shaft complexity, and roofing material. Light shaft framing and drywall adds $300–$800 depending on height and splay. Always budget for permits, flashing kit, and any deck repairs discovered after opening the roof.
Need help estimating total project cost? Read our project cost estimation guide.