Calculate the exact number of tiles needed for any floor or wall project, plus grout and thinset mortar. Supports 12×12, 18×18, 24×24, and custom tile sizes with adjustable waste factor.
Enter your room or wall dimensions, choose your tile size and grout joint width, and this calculator returns the number of tiles to buy, the grout weight, and the thinset mortar needed. Grout and thinset estimates scale with your tile size and joint width: larger tiles and narrower joints use less grout, while larger tiles require more thinset for full coverage.
Measure your floor or wall area in feet (length × width = square footage). Divide by the tile's coverage in square feet and multiply by your waste factor. A 12×12 tile covers exactly 1 sq ft; an 18×18 covers 2.25 sq ft; a 24×24 covers 4 sq ft. For a 10×8 ft bathroom floor using 12×12 tiles at 10% waste: 80 sq ft × 1.10 ÷ 1 sq ft = 88 tiles. Round up to the nearest full box.
For a diagonal (45°) layout, use a 15% waste factor: the extra cuts on the perimeter chew through material faster than a straight grid. Complex herringbone or offset patterns may need 20%.
The diagram below shows why professionals start layout from the center of the room instead of a corner: it keeps cut tiles balanced and roughly equal-sized on both sides, instead of a full tile against one wall and an awkward sliver against the other.
Corner-start layouts push all the cutting to one side, leaving a full-size sliver. Center-start layouts split the cuts evenly on both edges.
| Pattern | Recommended Waste | Why More Waste? |
|---|---|---|
| Straight grid (parallel to walls) | 10% | Minimal perimeter cuts; most cuts are used as fill pieces |
| Offset / brick bond (33% offset) | 10–12% | More cuts but still efficient; standard for subway tile |
| Diagonal (45°) | 15% | Perimeter pieces are cut at 45°; the off-cut is unusable |
| Herringbone | 15–20% | Short tiles, many cuts, complex angles |
| Irregular / mosaic | 20% | Custom fitting; trimming adds significant waste |
| Large format (24"+ tiles) | 15% | Fewer tiles means each broken tile is a bigger loss |
The grout joint width you choose determines which grout type to use. For joints under 1/8 inch, use unsanded grout: the fine particles fill tight joints cleanly without cracking. For joints 1/8 inch and wider, use sanded grout: the sand prevents the grout from shrinking and cracking as it cures in wider joints.
| Joint Width | Grout Type | Typical Use | Coverage (50 lb bag, 12×12 tile) |
|---|---|---|---|
| 1/16 in or less | Unsanded | Mosaic, glass tile | 90–120 sq ft (small tile increases joint density) |
| 1/8 in | Unsanded or sanded | Wall tile, ceramic | 250–330 sq ft |
| 3/16 in | Sanded | Floor tile, porcelain | 165–200 sq ft |
| 1/4 in or wider | Sanded | Large format, exterior | 135–145 sq ft |
Coverage figures are for 12×12 tile at each joint width; smaller tiles have more total joint length per square foot and use noticeably more grout. Always confirm with the coverage chart on your specific product.
Trowel notch size controls how much thinset is applied and affects coverage. Too thin and tiles won't bond properly: the back should be at least 95% covered when you press the tile down. Larger tiles require deeper notches to achieve full coverage, especially if your substrate isn't perfectly flat.
| Tile Size | Trowel Notch | Thinset Coverage (50 lb bag) | Notes |
|---|---|---|---|
| Up to 8×8 in | 3/16" V-notch | 50–60 sq ft | Mosaic and small ceramic |
| 12×12 in | ¼" square notch | 40–50 sq ft | Standard floor and wall tile |
| 13×13 to 18×18 in | ¼"×3/8" square notch | 35–45 sq ft | Medium format porcelain |
| 18×18 to 24×24 in | ½" square notch | 30–40 sq ft | Back-butter large tiles too |
| Over 24 in (large format) | ½"×½" square notch | 25–35 sq ft | Always back-butter; consider large-format thinset |
Tile is rigid and unforgiving of movement, so what's underneath it matters as much as the tile itself. The substrate needs to be flat, stable, and appropriate for wet or dry areas:
| Substrate | Tile-Ready? | Prep Needed |
|---|---|---|
| Concrete slab | Yes | Level high spots; check for cracks and moisture |
| Plywood subfloor | With prep | Add cement backer board or uncoupling membrane |
| OSB / particleboard | No, directly | Cover with backer board; never tile directly on OSB |
| Existing tile | With prep | Must be flat, sound, and clean; often better to remove |
| Vinyl or laminate | No | Remove first; too flexible to support tile |
Flatness tolerance for most tile installations is 1/8 inch of variation over a 10 ft span, or 1/16 inch over a 1 ft span, per the tile industry's ANSI standards. A subfloor that doesn't meet this needs self-leveling compound before tile goes down, especially for large-format tile, which shows lippage (uneven edges) much more visibly than small tile.
Planning a related project? See our flooring materials guide and general materials estimation guide.